CHROMABOND® Easy

CHROMABOND® Easy
Polar modified polystyrene-divinylbenzene copolymer with a weak anion exchanger

Specific surface 650 to 700 m²/g, particle size 80µm, pore size 50 Å, pH stability 1 to 14. Due to bifunctional modification much more hydrophilic than conventional polystyrene-divinylbenzene polymers and thus easily wettable with water.

Recommended applications: polar herbicides / pesticides from water (acidic, neutral, basic), polar phenols from water, polyaromatic compounds, polychlorinated biphenyls, drug analysis from urine, blood, serum, plasma pharmaceuticals / active ingredients from tablets, creams.

Due to the bifunctional modification CHROMABOND® Easy is considerably more hydrophilic than conventional polystyrene-divinylbenzene polymers and thus easily wettable with water. The Easy effect: Aqueous samples can be loaded directly without preconditioning! This means that little or even no conditioning is needed, in contrast to standard SPE materials, where recovery rates normally decrease, in the worst case down to zero! Depending on the separation task conditioning may be required and is recommended for method development. A positive side effect of the excellent wettability: there is no decrease of recovery rates, if the cartridge runs dry, therefore automation is easier or, in some cases compared to silica materials, only feasible with CHROMABOND® Easy, because a permanent vacuum can be used without supervision.

Further advantages of using a polymeric material:
-high surface, this means very high binding capacity (2 - 5 times higher than silica-based adsorbents)
-less adsorbent is needed in the cartridge (without losing sensitivity or recovery)
-faster analysis, because the height of the adsorbent bed can be reduced
-acidic or basic solvents (e. g. TFA) do not destroy the phase, or lead to unintended side products
Because of the polar modification the material is suitable for a broad range of compounds (acidic, neutral, basic, polar and nonpolar substances). Highly reproducible recovery rates can be obtained, even if the cartridge runs dry (especially advantageous when using 96-well plates, where stopcocks are not available!)

Tuotekoodi Valmistaja Nimi Volume (ml) Capacity (mg)
4003719 730751
Macherey-Nagel GmbH & Co. KG
CHROMABOND columns EASY volume: 1 ml, content of
30
1 30
4003720 730752
Lab Logistics Group GmbH
CHROMABOND columns EASY volume: 1 ml, content of
sorbent: 100 mg material: PP, pack of 30
4003721 730753
Macherey-Nagel GmbH & Co. KG
CHROMABOND columns EASY volume: 3 ml, content of
30
3 60
4003723 730754.250
Macherey-Nagel GmbH & Co. KG
CHROMABOND columns EASY BIGpack volume: 3 ml,
250
3 200
4003724 730755.250
Macherey-Nagel GmbH & Co. KG
CHROMABOND columns EASY BIGpack volume: 6 ml,
250
6 200
4003726 730757
Macherey-Nagel GmbH & Co. KG
CHROMABOND columns EASY volume: 15 ml, content of
20
15 500
4003727 730758
Lab Logistics Group GmbH
CHROMABOND columns EASY volume: 15 ml, content of
sorbent: 1000 mg material: PP, pack of 20
4003728 730759
Macherey-Nagel GmbH & Co. KG
CHROMABOND columns EASY volume: 3 ml, content of
30
3 500
6224850 730756
Macherey-Nagel GmbH & Co. KG
CHROMABOND columns EASY
30
6 500
6226452 730754
Macherey-Nagel GmbH & Co. KG
CHROMABOND columns EASY
30
3 200
6234375 730755
Macherey-Nagel GmbH & Co. KG
CHROMABOND columns EASY
30
6 200
BIGpacks: 4.003 723 / 4.003 724

Edustuksiamme

LLG tuoteluettelo