OPTIMA® 5 MS Accent capillary columns for GC
silarylene phase
-With polarity similar to a 5 % diphenyl -95 % dimethylpolysiloxane phase.
-USP G27, G36
-Lowest column bleed, nonpolar phase, ideal for ion trap and quadrupol MS detectors solvent rinsing for removal of impurities applicable
-Application areas: all-round phase for environmental analyses, trace analyses, EPA methods, pesticides, PCB, food and drug analyses
similar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MS
Max. temperature for isothermal operation: 340 °C,
Max. temperature for short isotherms in a temperature programme: 360 °C
for cloumns with film thicknesses > 5.5 µm the max. temperatures are 320 and 340 °C
Tuotekoodi | Valmistaja | Nimi | Int. diam. (mm) | Outer diam. (mm) | Film thickness (µm) | Length (m) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4003009 | 725811.30 Macherey-Nagel GmbH & Co. KG |
Capillary column OPTIMA 5-MS Accent ID: 0.32 mm, 1 |
0.32 | 0.5 | 0.250000 | 30 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4003010 | 725811.60 Macherey-Nagel GmbH & Co. KG |
Capillary column OPTIMA 5-MS Accent ID: 0.32 mm, 1 |
0.32 | 0.5 | 0.250000 | 60 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4003011 | 725812.25 Macherey-Nagel GmbH & Co. KG |
Capillary column OPTIMA 5-MS Accent ID: 0.32 mm, 1 |
0.32 | 0.5 | 1 | 25 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4003012 | 725812.60 Macherey-Nagel GmbH & Co. KG |
Capillary column OPTIMA 5-MS Accent ID: 0.32 mm, 1 |
0.32 | 0.5 | 1 | 60 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4003013 | 725813.30 Macherey-Nagel GmbH & Co. KG |
Capillary column OPTIMA 5-MS Accent ID: 0.32 mm, 1 |
0.32 | 0.5 | 0.500000 | 30 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4003017 | 725820.30 Macherey-Nagel GmbH & Co. KG |
Capillary column OPTIMA 5-MS Accent ID: 0.25 mm, 1 |
0.25 | 0.4 | 0.250000 | 30 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4003018 | 725820.60 Macherey-Nagel GmbH & Co. KG |
Capillary column OPTIMA 5-MS Accent ID: 0.25 mm, 1 |
0.25 | 0.4 | 0.250000 | 60 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4003019 | 725825.30 Macherey-Nagel GmbH & Co. KG |
Capillary column OPTIMA 5-MS Accent ID: 0.25 mm, 1 |
0.25 | 0.4 | 0.500000 | 30 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4003020 | 725825.60 Macherey-Nagel GmbH & Co. KG |
Capillary column OPTIMA 5-MS Accent ID: 0.25 mm, 1 |
0.25 | 0.4 | 0.500000 | 60 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4003021 | 725826.30 Macherey-Nagel GmbH & Co. KG |
Capillary column OPTIMA 5-MS Accent ID: 0.25 mm, 1 |
0.25 | 0.4 | 1 | 30 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4003022 | 725826.60 Macherey-Nagel GmbH & Co. KG |
Capillary column OPTIMA 5-MS Accent ID: 0.25 mm, 1 |
0.25 | 0.4 | 1 | 60 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen. Additionally, we supply the corresponding test mixture with each column. |