BOD Measuring system OxiTop®-IDS for determination of biogas/microbiology

BOD Measuring system OxiTop®-IDS for determination of biogas/microbiology
BOD measurement system for all types of respirometric measurements, e.g. soil respiration, microbiological activity measurement, biogas determination as well as extended BOD measurement for the industrial waste water plants and further degradation tests in 3 selectable measuring types, BOD standard, BOD special and pressure.
With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.
-Bluetooth®connectivity
-Direct calculation of all results in the meter
-Representation of curves for monitoring
-Parallel measurement of different examinations and methods
-Export to data acquisition programs
For the measurement of anaerobic degradability with OxiTop®-IDS/B measuring heads. The main application for these sets is the testing of fermentability of biological waste for biogas plants acc. to VDI 4630. The yield of methane can be measured in the pressure mode.
-Convenient and safe operation within an extended pressure range of up to 1500 hPa
-Pressure range excess warning
-Corrosion-proof head even in presence of H2S

Scope of supply:
OxiTop®-IDS AN6: 6 x OxiTop®-IDS/B measuring heads, 6 sample bottles MF45/1000 (1000 ml), nitrification inhibitor, 6 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS 6-Var
OxiTop®-IDS AN12: 12 x OxiTop®-IDS/B measuring heads, 12 sample bottles MF45/250 (250 ml), nitrification inhibitor, 12 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS-12

Please order CO2 absorber NHP 600 (9.303 403) separately.
The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.

Tuotekoodi Valmistaja Nimi Type
6275779 209724
Lab Logistics Group GmbH
OxiTop®-IDS AN6, 100 - 240 VAC, 50/60 Hz
Respirometric measuring system, 6 measuring pts
6275780 209726
Lab Logistics Group GmbH
Respirometric measuring system OxiTop®-IDS AN12
f. anaerobic measuring operation, 12 measuring pts
6314044 209725
Xylem Analytics Germany (WTW)
OxiTop®-IDS AN6, 100 - 240 VAC, 50/60 Hz
1
OxiTop®-IDS AN6
6314045 209727
Xylem Analytics Germany (WTW)
Respirometric measuring system OxiTop®-IDS AN12
1
OxiTop®-IDS AN12