High-temperature chamber furnaces with SiC rod heating LHTC/LHTCT 03/14 - 08/16 series
These powerful laboratory muffle furnaces are available for temperatures up to 1400 °C, 1500 °C, 1550 °C or 1600 °C. The durability of the SiC rods in periodic use, in combination with their high heating speed, make these furnaces the all-rounders in the laboratory. Heating times of 40 minutes to 1400 °C can be achieved, depending on the furnace
model and the conditions of use.
-Tmax 1400 °C, 1500 °C, 1550 °C or 1600 °C
-Working Temperature 1500 °C (for models LHTC ../16), increased wear and tear of heating elements must be expected in case of working at higher temperatures
-Insulation only made of materials that are classified as not carcinogenic acc. to TRGS 905, class 1 or 2
-Housing made of sheets of textured stainless steel
-Dual shell housing for low external temperatures and high stability
-Furnace room lined with durable fiber material, not classified
-Optional flap door (LHTC) which can be used as work platform or lift door (LHTCT) with hot surface facing away from the operator (HTCT 01/ only with lift door)
-Switching system with solid-state-relays, power tuned to the SiC rods
-Controller is the programmable C 550 with adjustable ramps and holding times
-Easy replacement of heating rods
-Adjustable air inlet opening, exhaust air opening in the roof
-400 V 3/N/PE 50/60 Hz connector as standard
Option:
-Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
-Square saggar for charging of up to three layers
-Lid for top saggar
-Manual or automatic gas supply system
-Process control and documentation via VCD software package for monitoring, documentation and control
Tuotekoodi | Valmistaja | Nimi | Type/Controller | Capacity (litres) | External dimensions (W x D x H) (mm) | Internal dimensions (W x D x H) (mm) | Rating (kW) | Temp. (max. °C) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6222778 | LC032K4DN Lab Logistics Group GmbH |
High temperature furnace LHTC O3/14/C450 with controller C 450, max. 1400°C |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
6235199 | LC032K6DN Nabertherm GmbH |
High-Temperature furnace LHTC 03/16/C550 1 |
LHTC 03/16/C550 | 3.0 | 415 x 545 x 490 | 120 x 210 x 120 | 9.0 | 1600 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
6252321 | LC082H4DN Lab Logistics Group GmbH |
High temperature furnace LHTCT 08/14/C450 with controller C 450, |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9764582 | LC032H4DN Lab Logistics Group GmbH |
High temperature furnace LHTCT 03/14/C450 with controller C 450, |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9764584 | LC032H5DN Lab Logistics Group GmbH |
High temperature furnace LHTCT 03/15/C450 with controller C 450, |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9764585 | LC082H5DN Lab Logistics Group GmbH |
High temperature furnace LHTCT 08/15/C450 with controller C 450, |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9764586 | LC012H6DN Nabertherm GmbH |
High temperature furnace LHTCT 01/16/C550 1 |
LHTCT 01/16/C550* | 1.5 | 340 x 300 x 460 | 110 x 120 x 120 | 3.5 | 1550 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9764587 | LC032H6DN Nabertherm GmbH |
High temperature furnace LHTCT 03/16/C550 1 |
LHTCT 03/16/C550* | 3.0 | 415 x 545 x 490 | 120 x 210 x 120 | 9.0 | 1600 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9764588 | LC082H6DN Nabertherm GmbH |
High temperature furnace LHTCT 08/16/C550 1 |
LHTCT 08/16/C550* | 8.0 | 490 x 625 x 540 | 170 x 290 x 170 | 13.0 | 1600 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9764589 | LC082K4DN Lab Logistics Group GmbH |
High temperature furnace LHTC 08/14/C450 with controller C 450, max. 1400°C |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9764590 | LC032K5DN Lab Logistics Group GmbH |
High temperature furnace LHTC 03/15/C450 with controller C 450, max. 1500°C |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9764591 | LC082K5DN Lab Logistics Group GmbH |
High temperature furnace LHTC 08/15/C450 with controller C 450, max. 1500°C |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9764592 | LC082K6DN Nabertherm GmbH |
High temperature furnace LHTC 08/16/C550 1 |
LHTC 08/16/C550 | 8.0 | 490 x 625 x 540 | 170 x 290 x 170 | 13.0 | 1600 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
* 220-240 V 1/N/PE 50/60 Hz connector as standard. Height plus max. 240 mm for the open LHTCT models.<BR>External dimensions vary for versions with additional equipment. Dimensions on request. |