Microcentrifuge 5430 / 5430 R (IVD)
Microcentrifuge with exceptional versatility. These centrifuges are used with e.g. rotors for Eppendorf Tubes® and PCR strips, rotors for microplates and 15/50 ml conical tubes, as well as a 48-place rotor, a 16-place rotor for Eppendorf Tubes® 5.0 ml and a swing-out rotor (24 x 1.5 / 2.0 ml).
Microcentrifuge 5430
-Choice of 8 different rotors, e.g. MTP rotor, Falcon rotor for max. versatility
-48 place centrifuge for 1.5ml/2.0ml micro test tubes, 6 x 50ml Falcon® tubes or 2 x MTP plates
-Unique 30 130xg
-Automatic rotor recognition
-Stores up to 50 routine programs
-Menu guided operation in 4 different languages
-Automatic lid opening following application sequence (only 5430)
Microcentrifuge 5430 R, additional features:
-Temp. range: -11°C to +40°C
-+4°C at max. speed with all rotors
-Continues cooling after the centrifugation process
-Fast Temp for achieving required temperature in shortest possible time
-Fast Temp pro for having the centrifuge refrigerated and ready-for-use at your desired pre-set time
Specifications 5430 // 5430 R
Max. RCF*: 30130 x g
Max. speed*: 17500 rpm
Max. capacity: 48 x 1.5/2.0ml or 6 x 50ml or 2 x MTP
Cooling temperature: - // -11 ... 40 °C
Timer: 30 s ... 99:59 h, with continuous run
Power consumption: 475 W // 1050 W
Dimensions (W x D x H) 330 x 420 x 250 mm // 380 x 640 x 290 mm
Weight: 29 kg // 56 kg
Power supply: 230 V, 50/60 Hz
Tuotekoodi | Valmistaja | Nimi | Type | Description | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9776730 | 5427000216 Eppendorf SE |
Micro centrifuges 5430 1 |
5430 (IVD) | with rotor FA-45-30-11, with membrane keypad | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9776731 | 5427000011 Eppendorf SE |
Micro centrifuges 5430 1 |
5430 (IVD) | without rotor, with membrane keypad | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9776732 | 5427000615 Eppendorf SE |
Micro centrifuge 5430 1 |
5430 (IVD) | without rotor, with dial setting | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9776733 | 5427000410 Eppendorf SE |
Microcentrifuge 5430 1 |
5430 (IVD) | with rotor FA-45-30-11, with dial setting | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9776734 | 5428000210 Eppendorf SE |
Microcentrifuge 5430 R 1 |
5430 R (IVD) | without rotor, with membrane keypad | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9776735 | 5428000619 Eppendorf SE |
Microcentrifuge 5430 R 1 |
5430 R (IVD) | without rotor, with dial setting | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9776736 | 5428000015 Eppendorf SE |
Microcentrifuge 5430 R 1 |
5430 R (IVD) | with rotor FA-45-30-11, with membrane keypad | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9776737 | 5428000414 Eppendorf SE |
Microcentrifuge 5430 R 1 |
5430 R (IVD) | with rotor FA-45-30-11, with dial setting | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
* depending on the installed rotor. |