BOD-Measurement-System BD 600

BOD-Measurement-System BD 600
BOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.

Scope of supply:
-BD 600, complete unit with 6 or 12* sensor heads and control unit with batteries
-Power supply unit incl. Y-cable for common power supply of BD 600 and stirring unit
-Inductive stirring unit
-6 or 12* sample bottles
-6 or 12* rubber gaskets
-6 or 12* magnetic stirring rods
-1 overflow flask, 157 ml
-1 overflow flask, 428 ml
-1 bottle, 50 ml potassium hydroxide solution
-1 bottle, 50 ml nitrification inhibitor solution
-1 instruction manual
-remote control
Specifications
Measuring principle: respirometric, electronic pressure sensor
Ranges: 0 - 40, 0 - 80, 0 - 200, 0 - 400, 0 - 800, 0 - 2000, 0 - 4000 mg/l O2
Measurement period: User-selectable, between 1 and 28 days
Power supply: 100-240 V, battery buffered or via power supply using Y-cable
Protection class: IP 54 (sensor head)
Interface: USB host port (USB stick), USB device port (computer), SD card
Clock: Real time
Application: BOD5 / BODF / OECD301F

Tuotekoodi Valmistaja Nimi Type Description
4678126 2444461
Tintometer GmbH
Complete system BD600 GLP
1
BD 600 GLP with 6 bottles, GLP conformity
6203214 418328
Tintometer GmbH
Sensor calibration set
1
Sensor Calibration Set for BSB/BOD Sensor
6250120 418644
Tintometer GmbH
Sample bottle glass BSB-5
1
BOD sample bottle 500 ml, amber
6268048 444460
Tintometer GmbH
Complete system BD600 BSB
1
BD 600 with 6 bottles
6280155 444465
Tintometer GmbH
Complete system BD606 BSB
1
BD 606 with 12 bottles
6314440 418676
Tintometer GmbH
Rubber sleeve (6.5 cm) for BD600 / BD606
1
Rubber sleeve (6.5 cm)
9303433 418642
Tintometer GmbH
Nitrification inhibitor
1
Nitrification inhibitor (N-ATH) liquid, bottle of 50 ml
9303436 418645
Tintometer GmbH
BOD/BSB sample bottle, glass
6
BOD sample bottle 500 ml, amber, 6 bottles
9303437 418636
Tintometer GmbH
Rubber sleeve (4.5 cm) for BD600 / BD606
1
Rubber sleeve (4.5 cm)
9303438 418634
Tintometer GmbH
Potassium hydroxide solution 45%
1
Kaliumhydroxid-Lösung 50 ml, 45 %
* 6 or 12 depending on BOD-System (BD600 or BD606)